        Low starting flow rate, minimum flow rate is 1/3 of traditional water meter.
        Water temperature detection, low temperature alarm.
        No moving part, no wear, long term stable operation.
        Above 10 years shelf life.
        Abnormal water usage alarm
        Installation at any angle, no influence for measurement accuracy.
        Ultrasonic signal quality detection.
        Photosensitive button, IP 68 design, long time under water working.
        Support M-Bus, optical and wireless communication interface;
        Compatible with  CJ/T 188, EN 13757;
        Compatible drinkable water standard requirement

  • Model : SC-7

 

ultrasonic water meter 

          Introduction

  •  The low starting flow, minimum flow rate is lower than the 1/3 of the traditional water meter;
  •  The water temperature detection, temperature alarm;
  •  No moving parts, no wear, can be long-term and stable operation;
  • The whole table is more than 10 years of life;
  •  Alarm for abnormal water use
  • Be installed at any angle, the measurement accuracy is not affected;
  • Ultrasonic signal  quality detection;
  • The photosensitive button;
  • The overall IP68 design, long-term immersion in the work;
  •  To support Infra-red, wM-Bus, M-Bus, RS485 etc.;
  •  Be compatible with GB/T 26831、CJ/T 188 and MODBUS RTU communication protocol;
  • The water meter is required in accordance with drinking water standards.

          Groundbreaking Performance

Application

For the accurate measurement of water content, and can provide records for a variety of applications of water supply pipeline and Transmit data.

Accuracy grade

2

Temperature grade

T50(T70, T30 optional)

Pressure loss grade

Δp40

Power supply

3.6V lithium battery

Battery life

More than 8 years

Average power consumption

≤0.05mW

Protection level

IP68

Maximum working pressure

1.6MPa

Climatic and mechanical environmental conditions

Class C (class B, class I optional)

Interface

Infra-red, wM-Bus, M-Bus, RS485

data storage

Daily cumulative volume (720 days), water use habits, failure information, and other daily data.

Range ratio(Q3/Q1)

250:1 (80:1100:1160:1400:1 can be customized)

Agreement

GB/T 26831、CJ/T 188 andMODBUS RTU

Maximum flow reading (m3)

99999.99999

          Interface

Infra-red

Switching menu and communication for liquid crystal display.

M-Bus

(600~9600)bps,Bus must use sectional area of not less than 0.75 mm2 shielded twisted pair, Single bus distance of not more than 1200 meters, Factory standard 1 meters

RS485

Using TI low power RS-485 transceiver, With TIA / EIA / 485A standard, Bus must use sectional area of not less than 0.75 mm2 shielded twisted pair, Factory standard 1 meters 

wM-Bus 

wM-Bus,868MHz,transmission power is less than or equal to +14dBm, the receiving sensitivity: -110dBm

GPRS

Independent intelligent monitoring system, a separate battery powered embedded inside the body. Support mobile Unicom SIM card, water meter data upload server, maintenance free, suitable for no power supply environment.

          Flow Rate Performance Data 

Nominal diameter DN(mm)

15

20

25

32

40

Maximum flow Q4( m3/h)

3.125

5

7.875

12.5

20

Common flow Q3( m3/h)

2.5

4.0

6.3

10.0

16.0

Boundary flux Q2( m3/h)

0.016

0.026

0.04

0.064

0.102

Minimum flow Q1( m3/h)

0.01

0.016

0.025

0.04

0.064

Pressure loss grade Δp

40

40

40

40

40

Pulse output equivalent(L)

0.1

0.1

0.5

0.5

0.5

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

Nominal diameter

15

20

25

32

40

L(mm)

165/110

190/130/195

260/160/225

260/180/230

300/200/245

L1(mm)

97

97

97

97

97

L2(mm)

259/204

294/234/299

380/280/345

380/300/350

428/328/373

H(mm)

91

91

91

128

139

H1(mm)

31

28

25

29

36

W(mm)

90

90

90

90

90

Table thread A(inch)

G3/4B

G1B

G11/4B

G11/2B

G2B

Union thread B(inch)

R1/2

R3/4

R1

R11/4

R11/2

 

 

Note: * for the default length

 

 

 

 

 

 

 

          Liquid crystal display

The user can switch the liquid crystal display interface through the photosensitive button:

  • First level menu is the basic measurement data display。
  • Second level menu is the reference data, such as the date, the first level address, the two level address, etc。
  •  If the water meter fails, it will display the corresponding fault alarm symbol in the decimal part of the positive cumulative volume。
  •  Any display item of the first level menu is quick to sense the light sensitive button 2 seconds, at least 4 times ,the display can enter the two level menu,Or use the factory's mobile phone reading assistant APP mobile client to enter。
  •  Factory default forward flow measurement (data is positive minus reverse data). If you need to reverse the measurement required in order to explain.

Note:

  •  The water temperature is lower than 4 When the alarm
  •  The transducer signal is lower than the standard value 30% when the alarm
  •  Battery power lower than 3.2V alarm
  • Air traffic control indicator is optional, and the default Air traffic alarm is open.

 

 